[1]
|
Zhang J, Xing SX, Qiu X, Wang LF, Zhang LB. PCD used in monitoring sterilization efficacy of hydrogen peroxide gas plasma sterilizer. Chin J Nosocomiol 2009;19(12):1531 − 3. http://dx.doi.org/10.3321/j.issn:1005-4529.2009.12.022CrossRef
|
[2]
|
AAMI. AAMI TIR31: 2003 Process challenge devices/test packs for use in health care facilities. Arlington, VA: Association for the Advancement of Medical Instrumentation, 2003. https://store.aami.org/s/store#/store/browse/detail/a152E000006j609QAA.https://store.aami.org/s/store#/store/browse/detail/a152E000006j609QAA |
[3]
|
State Administration for Market Regulation, Standardization Administration. GB 27955-2020 Hygienic requirements for low-temperature hydrogen peroxide gas plasma sterilizer. Beijing: China Standard Press, 2020. (In Chinese). |
[4]
|
Ban HQ. Disinfection monitoring technology guide in health care. Zhengzhou: Zhengzhou University Press. 2017: 115-8. (In Chinese). |
[5]
|
Standards Policy and Strategy Committee. EN 867-5: 2001 Non-biological systems for use in sterilizers-Part 5: specification for indicator systems and process challenge device for use in performance testing for small sterilizers Type B and Type S. European Committee for Standardization, 2001. https://www.en-standard.eu/csn-en-867-5-non-biological-systems-for-use-in-sterilizers-part-5-specification-for-indicator-systems-and-process-challenge-devices-for-use-in-performance-testing-for-small-sterilizers-type-b-and-type-s/.https://www.en-standard.eu/csn-en-867-5-non-biological-systems-for-use-in-sterilizers-part-5-specification-for-indicator-systems-and-process-challenge-devices-for-use-in-performance-testing-for-small-sterilizers-type-b-and-type-s/ |
[6]
|
You N, Yao Y, Zhang X. Cycle mode and effect evaluation method of hydrogen peroxide plasma sterilization. Chin J Nosocomiol 2017;27(3):705 − 9. http://dx.doi.org/10.11816/cn.ni.2016-162940 (In Chinese). CrossRef
|
[7]
|
Ding ZM, Gao XN, Yu YQ, Zou YF, Zhang Y, Wang JM, et al. Management of quality of sterilization with hydrogen peroxide low temperature plasma. Chin J Nosocomiol 2014;24(24):6238 − 40. http://dx.doi.org/10.11816/cn.ni.2014-144192 (In Chinese). CrossRef
|
[8]
|
Unger-Bimczok B, Kosian T, Kottke V, Hertel C, Rauschnabel J. Hydrogen peroxide vapor penetration into small cavities during low-temperature decontamination cycles. J Pharm Innov 2011;6(1):32 − 46. http://dx.doi.org/10.1007/s12247-011-9097-3CrossRef
|
[9]
|
Kanemitsu K, Imasaka T, Ishikawa S, Kunishima H, Harigae H, Ueno K, et al. A comparative study of ethylene oxide gas, hydrogen peroxide gas plasma, and low-temperature steam formaldehyde sterilization. Infect Control Hosp Epidemiol 2005;26(5):486 − 9. http://dx.doi.org/10.1086/502572CrossRef
|
[10]
|
Rutala WA, Gergen MF, Weber DJ. Comparative evaluation of the sporicidal activity of new low-temperature sterilization technologies: ethylene oxide, 2 plasma sterilization systems, and liquid peracetic acid. Am J Infect Control 1998;26(4):393 − 8. http://dx.doi.org/10.1016/S0196-6553(98)70034-3CrossRef
|